Water rots wood, corrodes metal, and feeds mold. A Passive House enclosure is thicker, better insulated, and far more airtight than usual. Its outer layers run colder in winter, and no leaking air dries it out, so its moisture control has to be designed.

Keep liquid water out, expect some vapor to get in, and make sure the assembly can dry. Air leaking through gaps usually carries more vapor than diffusion through materials, so the airtight layer is the first vapor control. Each remaining layer should be chosen so the wall or roof can dry to at least one side, with no two vapor-tight layers trapping moisture between them. Which side depends on climate: in a cold climate the warm, humid air is inside in winter; in a hot, humid one it's outside. Variable, or "smart," vapor retarders, which tighten when dry and open when humid, are widely used where an assembly has to dry both ways.

PHI doesn't prescribe a vapor retarder or a permeance. It sets the outcome: no excessive moisture build-up in any section or detail, and inside surfaces warm enough to stay free of mold. For riskier cases, such as interior insulation, some flat and green roofs, and insulated assemblies in hot, humid climates, the certifier can ask for a hygrothermal simulation, a model of heat and moisture through the seasons. PHI also limits how often indoor humidity can run high.